The 73 Series hygienic multi stack cartridge housing is available with 3, 5, 8 & 12 element stacks up to 40" long. The 'T' style configuration with dome cover is equipped with a Cast Vee clamp as standard for pressures ranging from 6 - 10 bar.g. This leg mounted, free standing housing with domed cover, is the ideal choice for all hygienic systems when using Single Open End plug in style cartridges. The simple to lift off lightweight dome allows full and easy access to the cartridges for rapid changeouts, and the housings can be dismantled for full cleandowns.

Bolted closures are an option available for all models.

The 73 Series housing will accept the full range of Amazon Single Open End industry standard cartridges ranging from 0.03 to 40µm with nominal lengths of 10, 20, 30 and 40".

PED Compliance - CE Marked.

    Features include:

  • 'T' style construction with a high specification hygienic finish and optional electropolish inside and out.
  • Quick release Vee clamp closure for ease of access.
  • Standard single open end cartridge fitting, using either code 8 or Bayonet lock code 7 for forward and reverse flow direction.
  • Easy to lift off lightweight dome allows excellent access for cartridge changeout.
  • Designed to allow complete stripdown to aid ease of cleaning.
  • 316L construction for maximum corrosion resistance.
  • No loose internals for trouble free operation.
  • Every housing is etched with a serial number for full traceability.
  • Wide range of options available for the connection size and style, cartridge lengths and materials of construction.
  • Accessories available include pressure gauges, hygienic vent valve and Tri Clamp flange adapter.

 Housing Size Selection
The 73 Series hygienic multi stack cartridge housing are available in 3, 5, 8 and 12 stack configurations. To view full technical specifications, click on the most appropriate housing model type from the options shown below:

Model Type Number Of Cartridge Stacks Cartridge Lengths Standard Connections Suggested Flow Rate Range (lt/min)
73 Series 3 Stack 3 10", 20", 30" 1½" Tri Clamp 30-225
73 Series 5 Stack 5 10", 20", 30" 2" Tri Clamp 50-375
73 Series 8 Stack 8 20" or 30" 2½" Tri Clamp 160-600
73 Series 12 Stack 12 20" or 30" 3" Tri Clamp 240-900

 3 Stack
Return to housing size selection
 Specification Data - 73 Series Hygienic 3 Stack Cartridge Housing
Number of Cartridges 3
Nominal Cartridge Length 10", 20" or 30"
Cartridge End Cap Style Code 7 -BS226 Double bayonet with spear
Code 8 -BS222 with spear
Code A -Double 'O ring with spear
Closure Style Cast Vee Clamp
Connection Type 1½" Tri Clamp,
1½" Stub pipe, Sanitary Fittings including DIN 11851, RJT, SMS and IDF
Material 316L St. Steel or Hastelloy C22 (limited options - Please refer to Sales Office)
Gasket/Seal Silicone, Viton or FEP/Silicone
Finish Mechanically polished inside and out, option of electropolishing
Vent Standard: ¼" BSPF fitted with plug
Options: 1½" Tri Clamp (no clamp/blind)
1½" Tri Clamp with ¼" Vent, Hygienic valve assembly with PTFE seat and hose barb


Return to housing size selection
 Technical Data - 73 Series Hygienic 3 Stack Cartridge Housing
Housing Series 73 Series Hygienic 3 Stack Cartridge Housing
Nominal Cartridge Length 10" 20" 30"
Max. Operating Pressure (Bar g) Vee Clamp = 10
Max. Operating Temperature (° C) 110
Volume (litres)* 11.4 19.4 27.4
Dry Weight (Kg)* 14.2 21.2 14.2
*Volumes and weights are approximate; if these details are critical, then please refer to Amazon technical sales for exact details.


Return to housing size selection
 Suggested Flow Rate (lt/min)
Housing Series 73 Series Hygienic 3 Stack Cartridge Housing
Nominal Cartridge Length 10" 20" 30"
>50µm Rated Cartridge 75 150 225
10-50µm Rated Cartridge 60 120 180
1µm - 10µm Rated Cartridge 45 90 135
<1µm Rated Cartridge 30 60 90
CAUTION: Suggested flow rates shown are for water viscosity liquids using depth type filters. They take no account of viscosity, dirt loading or pressure loss. Flow rate directly influences cartridge life and efficiency; for optimum performance it is advisable to select as low a flow rate per cartridge as possible.


 5 Stack
Return to housing size selection
 Specification Data - 73 Series Hygienic 5 Stack Cartridge Housing
Number of Cartridges 5
Nominal Cartridge Length 10", 20" or 30"
Cartridge End Cap Style Code 7 -BS226 Double bayonet with spear
Code 8 -BS222 with spear
Code A -Double 'O ring with spear
Closure Style Cast Vee Clamp
Connection Type 2" Tri Clamp
2" Stub pipe, Sanitary Fittings including DIN 11851, RJT, SMS and IDF
Material 316L St. Steel or Hastelloy C22 (limited options - Please refer to Sales Office)
Gasket/Seal Silicone, Viton or FEP/Silicone
Finish Mechanically polished inside and out, option of electropolishing
Vent Standard: ¼" BSPF fitted with plug
Options: 1½" Tri Clamp (no clamp/blind) or 1½" Tri Clamp with ¼" Vent, Hygienic valve assembly with PTFE seat and hose barb


Return to housing size selection
 Specification Table - 73 Series Hygienic 5 Stack Cartridge Housing
Housing Series 73 Series Hygienic 5 Stack Cartridge Housing
Nominal Cartridge Length 10" 20" 30"
Max. Operating Pressure (Bar g) Vee Clamp = 10
Max. Operating Temperature (° C) 110
Volume (litres)* 14.2 23.3 32.4
Dry Weight (Kg)* 19 22.5 26
*Volumes and weights are approximate; if these details are critical, then please refer to Amazon technical sales for exact details.


Return to housing size selection
 Suggested Flow Rate (lt/min)
Housing Series 73 Series Hygienic 5 Stack Cartridge Housing
Nominal Cartridge Length 10" 20" 30"
>50µm Rated Cartridge 125 250 375
10-50µm Rated Cartridge 100 200 300
1µm - 10µm Rated Cartridge 75 150 225
<1µm Rated Cartridge 50 100 150
CAUTION: Suggested flow rates shown are for water viscosity liquids using depth type filters. They take no account of viscosity, dirt loading or pressure loss. Flow rate directly influences cartridge life and efficiency; for optimum performance it is advisable to select as low a flow rate per cartridge as possible.


 8 Stack
Return to housing size selection
 Specification Data - 73 Series Hygienic 8 Stack Cartridge Housing
Number of Cartridges 8
Nominal Cartridge Length 20" or 30"
Cartridge End Cap Style Code 7 -BS226 Double bayonet with spear
Code 8 -BS222 with spear
Code A -Double 'O ring with spear
Closure Style Cast Vee Clamp
Connection Type 2½" Tri Clamp
2½" Stub pipe, Sanitary Fittings including DIN 11851, RJT, SMS and IDF
Material 316L St. Steel or Hastelloy C22 (limited options - Please refer to Sales Office)
Gasket/Seal Silicone, Viton or FEP/Silicone
Finish Mechanically polished inside and out, option of electropolishing
Vent Standard: ¼" BSPF fitted with plug
Options: 1½" Tri Clamp (no clamp/blind) or 1½" Tri Clamp with ¼" Vent, Hygienic valve assembly with PTFE seat and hose barb


Return to housing size selection
 Technical Data - 73 Series Hygienic 8 Stack Cartridge Housing
Housing Series 73 Series Hygienic 8 Stack Cartridge Housing
Nominal Cartridge Length 20" 30"
Max. Operating Pressure (Bar g) Vee Clamp = 10
Max. Operating Temperature (° C) 110
Volume (litres)* 43.9 61.9
*Volumes and weights are approximate; if these details are critical, then please refer to Amazon technical sales for exact details.


Return to housing size selection
 Suggested Flow Rate (lt/min)
Housing Series 73 Series Hygienic 8 Stack Cartridge Housing
Nominal Cartridge Length 20" 30"
>50µm Rated Cartridge 400 600
10-50µm Rated Cartridge 320 480
1µm - 10µm Rated Cartridge 240 360
<1µm Rated Cartridge 160 240
CAUTION: Suggested flow rates shown are for water viscosity liquids using depth type filters. They take no account of viscosity, dirt loading or pressure loss. Flow rate directly influences cartridge life and efficiency; for optimum performance it is advisable to select as low a flow rate per cartridge as possible.


 12 Stack
Return to housing size selection
 Specification Data - 73 Series Hygienic 12 Stack Cartridge Housing
Number of Cartridges 12
Nominal Cartridge Length 20" or 30"
Cartridge End Cap Style Code 7 -BS226 Double bayonet with spear
Code 8 -BS222 with spear
Code A -Double 'O ring with spear
Closure Style Cast Vee Clamp
Connection Type 3" Tri Clamp
3" Stub pipe, Sanitary Fittings including DIN 11851, RJT, SMS and IDF
Material 316L St. Steel or Hastelloy C22 (limited options - Please refer to Sales Office)
Gasket/Seal Silicone, Viton or FEP/Silicone
Finish Mechanically polished inside and out, option of electropolishing
Vent Standard: ¼" BSPF fitted with plug
Options: 1½" Tri Clamp (no clamp/blind) or 1½" Tri Clamp with ¼" Vent, Hygienic valve assembly with PTFE seat and hose barb


Return to housing size selection
 Technical Data - 73 Series Hygienic 12 Stack Cartridge Housing
Housing Series 73 Series Hygienic 12 Stack Industrial Cartridge Housing
Nominal Cartridge Length 20" 30"
Max. Operating Pressure (Bar g) Vee Clamp = 10
Max. Operating Temperature (° C) 110
Volume (litres)* 61.4 85.9
*Volumes and weights are approximate; if these details are critical, then please refer to Amazon technical sales for exact details.
Return to housing size selection
 Suggested Flow Rate (l/min)
Housing Series 73 Series Hygienic 12 Stack Cartridge Housing
Nominal Cartridge Length 20" 30"
>50µm Rated Cartridge 600 900
10-50µm Rated Cartridge 480 720
1µm - 10µm Rated Cartridge 360 540
<1µm Rated Cartridge 240 360
CAUTION: Suggested flow rates shown are for water viscosity liquids using depth type filters. They take no account of viscosity, dirt loading or pressure loss. Flow rate directly influences cartridge life and efficiency; for optimum performance it is advisable to select as low a flow rate per cartridge as possible.

Home | Contact Webmaster | Privacy Policy | Copyright | Trademark | Disclaimer | Conditions of Sale | Links
Amazon Filters Ltd.
Albany Park Estate, Frimley Road Camberley, Surrey GU16 7PG UK Tel: +44 (0) 1276 670600 Fax: +44 (0) 1276 670101 www.amazonfilters.co.uk
British Standards Institute Accreditation sales@amazonfilters.co.uk